AYO™ WX FFM-DS Double-Seal Full-Face Mask PAPR Systems
Choose your system:
The system includes everything to get started, but to save the trouble of buying new filters soon, we recommend buying together some packs of spare filters according to your normal working condition and frequency of use.
SKU: N/A
分类: AYO WX Powered Air Purifying Respirator (PAPR)
Verify the Mask Size
| FFM-DS (Double-Seal) | |
| Mask Size | Recommended Height |
| Medium – Large | 110-140 mm |
Note:
- User protection is compromised when tight-fitting Mask Assembly does not fit the user properly.
- Always perform the Fit Test assessment for better fit and protection for tight-fitting masks.
AYO™ WX FFM-DS PAPR – a Double-seal Tight-fitting full-face mask PAPR series, comprising 2 models:
- AYO™ WX FFM-DS 颗粒物-气流增强型 Double-Seal Full-Face Mask PAPR System
- AYO™ WX FFM-DS 气体 Double-Seal Full-Face Mask PAPR System (coming soon!)
This series is designed for demanding breathing protection including eye protection, and suitable in industrial and healthcare settings.
AYO™ WX FFM-DS Double-Seal PAPR System sets a new standard for full-face powered respirators.
- Key Features
- Key Benefits
- Technical Specifications
- Training Videos
- User Manuals and Quick Guides
- Certifications
- A unique double-seal, the first of its kind in the world, achieving unprecedented fit factor of over 2000.
- Exceptionally Clear and scratch-resistant lens with a magnificent field of view.
- No hose, no belt, easy to don and doff.
- Up to 220L/Min peak flow (P-Boost).
- Advanced breath-responsive flow control.
- Interchangeable to AYO WX FFM-LF loose-fitting full-face mask with the Changeover Kit.
- Industry-leading built-in speech diaphragm.
- Shower Kit add-on: for decontamination showers.
- Easier to clean and maintain than traditional PAPRs.
- Offering very high protection even when the pressure inside the mask briefly falls to negative during very heavy breathing.
- Increasing productivity for work involving high exertion, substantial body movement, and in confined spaces.
- Ensuring protection and WHS compliance economically.
| Compliance | Respiratory Protection | EN 12942: 2023 TM3P EN 12942: 2023 TM3A1P MS EN 12942: 2023 TM3A1B1E1K1P MS (coming soon) AS/NZS 1716:2012 PAPR-P3 |
| Eye/Face Protection |
AS/NZS 1337.1:2010 ISO 16321-1-2021 |
|
| EMC | CISPR 11: 2017+A1:2020 | |
| EN IEC 61326-1:2021 | ||
| EN IEC 61326-2-2:2021 | ||
| EN IEC 61000-3-2:2019/A1:2021 | ||
| EN 61000-3-3:2013/A2:2021 | ||
| 47 CFR FCC part 15, Subpart B | ||
| ANSI C63.4:2014 | ||
| Safety | AS/NZS 61558, EN 61558, UL 62368 | |
| Product Certification | Europe: TBD Australia: CMI PC10112 |
|
| Filter Options | Main Filter – Long Life | P3/TM3, Pack of 3, Use up to 6 months |
| Pre-filter | Pack of 10, replaced when blocked or dirty | |
| Pre-filter – Anti-odour | Pack of 10, replaced when blocked or odour present | |
| Gas cartridge A1B1E1K1 (coming soon) | Pack of 1, use up to 6 months | |
| Gas cartridge A1 | ||
| HEPA filter for the Gas cartridge | Pack of 3, Use up to 6 months | |
| Mask Size | ML – Fit Chin to Nose-bridge Height 110mm – 140mm | |
| Operation Conditions | Altitude | Up to 5000m |
| Temperature | -10°C to 50°C | |
| Humidity | Up to 95% (non-condensing) | |
| Storage Conditions |
Temperature and Humidity |
Short period < 1 month: -5°C to 45°, 65±20%RH Within 3 months: -5°C to 35°C, 65±20%RH Long period > 3 months: 0°C to 35°C, 65±20%RH |
| Battery Run Time | 颗粒物 | Typically, 8 – 16 hours depending on the actual workload and dust concentration. |
| Battery Charging | 3.5 hours to 95% (fast flashing LED) 4 hours full charge (Constant LED) |
|
| Battery Life | Typical 3 years, replaceable | |
| Peak Flow | 颗粒物 | Up to 220 l/min |
| 气体 | Up to 130 l/min | |
| Manufacturer Minimum Flow Condition | 颗粒物 | 115 l/min |
| 气体 | 95 l/min | |
| Alarms | Filter-Blocked Alarm | 2 beeps per second, flashing Red LED |
| Low Battery Alarm | 3 beeps per second | |
| Flow Capacity Test | Peak flow check | 3 levels |
| Noise Level | Leq (high exertion) | Up to 71dB |
| Leq (typical) | < 65dB | |
| Weight | Power Unit – Particulate | 437g |
| Power Unit – Gas | 429g | |
| FFM-DS Full-Face Mask (ML) | 580g | |
| Filter Unit – Particulate | 126g | |
| Filter Unit – Gas | 315g | |
| 使用寿命 | Motor/blower | Over 10 years |
| AC Charge Adaptor | Input | 100 ~ 240VAC, 47~60 Hz |
| Output | 13.8VDC, 1A | |
| DC Jack plug | 1.1mm ID, 3.0mm OD |
Aimwell™ AYO™ WX FFM
- Full-Face Mask System Donning and Doffing
- Full-Face Mask
- Full-Face Plug Sheath
- FFM Face Seal Kit
Aimwell™ AYO™ WX Main Unit
- Changing Filters
- Main Unit Basic Operation
- Control Panel
- Operation Mode
- Basic Diagnostics
- Battery Charging
- Battery Replacement
- Older version (before 2025)
- New version (after 2025)
- Push-Fit & Twist-Release Connection Cleaning
- Main Unit Dust Sleeve
- Cleaning
Aimwell™ AYO™ TALK-MIC
AYO™ WX User Manuals:
AYO™ WX FFM Quick Guides:
- AS/NZS 1716: 2012 PAPR P3
- EN 12941: 2023 TH3
see more: AYO WX Certifications
RELATED PRODUCTS
澳大利亚标准认证
澳大利亚拥有及运营
Free Shipping within Australia
*for purchases with a minimum order value of $100.
30 Day Product Return
*terms and conditions apply.