AYO™ WX FFM-DS Double-Seal Full-Face Mask PAPR Systems

Choose your system:

The system includes everything to get started, but to save the trouble of buying new filters soon, we recommend buying together some packs of spare filters according to your normal working condition and frequency of use.

  Verify the Mask Size

FFM-DS (Double-Seal)
Mask Size Recommended Height
Medium – Large 110-140 mm

Note:

  • User protection is compromised when tight-fitting Mask Assembly does not fit the user properly.
  • Always perform the Fit Test assessment for better fit and protection for tight-fitting masks.

AYO™ WX FFM-DS PAPR – a Double-seal Tight-fitting full-face mask PAPR series, comprising 3 models:

  • AYO™ WX FFM-DS P-Standard Double-Seal Full-Face Mask PAPR System (Discontinued)
  • AYO™ WX FFM-DS P-Boost Double-Seal Full-Face Mask PAPR System
  • AYO™ WX FFM-DS Gas Double-Seal Full-Face Mask PAPR System (coming soon!)

This series is designed for demanding breathing protection including eye protection, and suitable in industrial and healthcare settings.

AYO™ WX FFM-DS Double-Seal PAPR System sets a new standard for full-face powered respirators.

  • A unique double-seal, the first of its kind in the world, achieving unprecedented fit factor of over 2000.
  • Exceptionally Clear and scratch-resistant lens with a magnificent field of view.
  • No hose, no belt, easy to don and doff.
  • Up to 220L/Min peak flow (P-Boost).
  • Advanced breath-responsive flow control.
  • Interchangeable to AYO WX FFM-LF loose-fitting full-face mask with the Changeover Kit.
  • Industry-leading built-in speech diaphragm.
  • Shower Kit add-on: for decontamination showers.
  • Easier to clean and maintain than traditional PAPRs.
  • Offering very high protection even when the pressure inside the mask briefly falls to negative during very heavy breathing.
  • Increasing productivity for work involving high exertion, substantial body movement, and in confined spaces.
  • Ensuring protection and WHS compliance economically.

Technical Specifications (Complete AYO WX Series):

Compliance Respiratory Protection Standards AYO WX FFM-LF P-Boost Loose-Fitting
Full-Face Mask PAPR System
EN 12941:2023 TH3P MS
AS/NZS 1716:2012 PAPR-P3
AYO WX HFM P-Boost Dual-Fitting Standard
Half-Face Mask PAPR System

AYO WX HFM-W P-Boost Dual-Fitting Welding
Half-Face Mask PAPR System

EN 12941:2023 TH3P MS
EN 12942: 2023 TM3P MS (TBA)
AS/NZS 1716:2012 PAPR-P3
AYO WX FFM-DS P-Boost Double-Seal
Full-Face Mask PAPR System

AYO WX FFM-DS Gas Double-Seal
Full-Face Mask PAPR System

AYO WX HFM Gas Tight-Fitting Standard
Half-Face Mask PAPR System

AYO WX HFM-W Gas Tight-Fitting Welding
Half-Face Mask PAPR System

EN 12942: 2023 TM3P MS (TBA)
EN 12942: 2023 TM3A1B1E1K1P MS (TBA)
AS/NZS 1716:2012 PAPR-P3

“MS” indicates the product has passed all the mechanical strength tests per EN12941:2023 and EN12942:2023.

Eye/Face Protection AYO WX FFM-LF, AYO WX FFM-DS AS/NZS 1337.1:2010
(Low Impact and flame impingement Protection)
Respiratory Protection Certification Australia CMI ProdCert, Lic: PC10112
CE Mark CE 2384 Module B+D
EMC CISPR 11: 2017+A1:2020
EN IEC 61326-1:2021
EN IEC 61326-2-2:2021
EN IEC 61000-3-2:2019/A1:2021
EN 61000-3-3:2013/A2:2021
47 CFR FCC part 15, Subpart B
ANSI C63.4:2014
Safety AS/NZS 61558, EN 61558, UL 62368
Filter Options Main Filter – Long Life P3, TM3P Pack of 3, use up to 6 months
Main Filter – P3 Standard Pack of 3, use up to 3 months
Pre-filter Pack of 10, replaced when blocked or dirty
Pre-filter – Anti-odour Pack of 10, replaced when blocked or odour present
Gas cartridge A1B1E1K1 Pack of 1, use up to 6 months
HEPA filter for the Gas cartridge TM3P Pack of 3, Use up to 6 months
Operation Conditions Altitude Up to 5000m
Temperature – 10°C to 50°C (14°F to 122°F)
Humidity Up to 95% (non-condensing)
Storage Condition Temperature and Humidity Short period < 1 month -5°C to 45°C 23°F to 113°F), 65±20%RH
Within 3 months -5°C to 35°C (23°F to 95°F), 65±20%RH
Long period > 3 months 0°C to 35°C (32°F to 95°F), 65±20%RH
Battery Run Time Particulate Minimum 4 hours,
typically 16 hours for Eco State, 8 hours for Boost State
Gas Minimum 4 hours, typically 9 hours
Battery Charging Within the unit with an external charger provided, 0°C to 35°C 3.5 hours to 95% (fast flashing LED)
4 hours full charge (Constant LED)
Battery Life Typical 3 years, replaceable
Peak Flow Particulate Over 220 l/min
Gas Over 140 l/min
Manufacturer Minimum Flow Condition Particulate 120 l/min
Gas 95 l/min
Alarms Filter-Blocked Alarm 2 beeps per second, flashing Red LED
Low Battery Alarm 3 beeps per second
Flow Capacity Check Peak flow check 3 levels
Noise Level Leq – high exertion Up to 71dB
Leq – typical < 65dB
Weight Power Unit – Particulate 437g
Power Unit – Gas 429g
Service life Motor/Blower 10 years
AC Charge Adaptor Input 100 ~ 240VAC, 47~60 Hz
Output 13.8VDC, 1A
DC Jack plug 1.1mm pin, 3.0mm barrel
  • AS/NZS 1716: 2012 PAPR P3
  • EN 12941: 2023 TH3

see more: AYO WX Certifications

RELATED PRODUCTS

AYO WX FFM DS-To-LF Changeover Kit

$31.20

AYO WX PAPR P3 Main Filter – Long Life (Pack of 3)

$79.30

AYO WX Pleated Pre-Filter (Pack of 10)

$31.20

AYO FFM Lens Protective Film – Clear (Pack of 10)

$23.40

Certified with Australian Standard

Australian Owned & Operated

Free Shipping within Australia

*for purchases with a minimum order value of $100.

30 Day Product Return

*terms and conditions apply.
0
    0
    Your Cart
    Your cart is emptyReturn to Shop