AYO™ WX FFM-LF Loose-Fitting Full-Face Mask
PAPR System
Choose your system:
Verify the Mask Size
| FFM-LF (Loose-Fitting) | |
| Mask Size | Recommended Height |
| Medium – Large | 95-140 mm |
AYO™ WX FFM-LF PAPR – a loose-fitting full-face mask PAPR system within AYO™ WX around-neck modular PAPR series, comprising 3 models:
- AYO™ WX FFM-LF P-Standard Loose-Fitting Full-Face Mask PAPR System (discontinued)
- AYO™ WX FFM-LF P-Boost Loose-Fitting Full-Face Mask PAPR System
- AYO™ WX FFM-LF Gas Loose-Fitting Full-Face Mask PAPR System (coming soon!)
This series is designed for demanding breathing protection in dusty or toxic industrial settings, such as:
- Formwork.
- Building demolition and restoration.
- Concrete patching.
- Tunnelling.
- Mining.
It is also designed to be compatible with facial hair and to provide eye and face protection.
Different from the AYO™ WX FFM-DS Double-Seal Tight-Fitting PAPR, its full-face mask doesn’t include an inner mask. Although its protection level is less than a well-fitted AYO™ WX FFM-DS PAPR when breathing hard, it can still provide PAPR P3 protection for light to moderate exertion.
This state-of-the-art and patented powered full-face mask represents the best PAPR technology in the world. It sets a new standard of high-level respiratory protection as well as eye and face protection for workers with facial hair.
The system includes everything to get started, but to save the trouble of buying new filters soon, we recommend buying together some packs of spare filters according to your normal working conditions and frequency of use.
特点:
- No hose, no belt, no hassles.
- Over 220L/Min peak flow (P-Standard and P-Boost).
- Advanced breath-responsive flow control.
- Compact and lightweight.
- Exceptional field of view.
- An add-on face seal kit: particularly suited for workers with longer beards.
- Lighter, cooler, easier to clean and maintain than traditional PAPRs
- Beard compatible: no need to be clean-shaven.
- No fit testing is required.
- Great protection: 40 times better than P2 non-powered respirators.
- Improve productivity.
- Exceptional value for money
| Compliance | Respiratory Protection Standards | All models | AS/NZS 1716:2012 PAPR-P3 (P3 filter filtration efficiency) |
| AYO WX FFM-LF P-Boost Loose-Fitting Full-Face Mask PAPR System | EN 12941:2023 TH3P MS | ||
| AYO WX HFM P-Boost Dual-Fitting Standard Half-Face Mask PAPR System
AYO WX HFM-W P-Boost Dual-Fitting Welding Half-Face Mask PAPR System |
EN 12941:2023 TH3P MS
EN 12942: 2023 TM3P MS |
||
| AYO WX FFM-DS P-Boost Double-Seal Full-Face Mask PAPR System
AYO WX FFM-DS Gas Double-Seal Full-Face Mask PAPR System AYO WX HFM Gas Tight-Fitting Standard Half-Face Mask PAPR System AYO WX HFM-W Gas Tight-Fitting Welding Half-Face Mask PAPR System |
EN 12942: 2023 TM3P MS
EN 12942: 2023 TM3A1B1E1K1P MS |
||
| Eye/Face Protection | AYO WX FFM-LF, AYO WX FFM-DS | AS/NZS 1337.1:2010
(Low Impact and flame impingement Protection) |
|
| Respiratory Protection Certification | Australia | CMI ProdCert, Lic: PC10112 | |
| CE Mark, UKCA | CE 2384 Module B+D | ||
| Refer to Certificate and Declaration of Conformity (DoC) | |||
| EMC | CISPR 11: 2017+A1:2020 | ||
| EN IEC 61326-1:2021 | |||
| EN IEC 61326-2-2:2021 | |||
| EN IEC 61000-3-2:2019/A1:2021 | |||
| EN 61000-3-3:2013/A2:2021 | |||
| 47 CFR FCC part 15, Subpart B | |||
| ANSI C63.4:2014 | |||
| Safety | AS/NZS 61558, EN 61558, UL 62368 | ||
| Filter Options | Main Filter – Long Life PAPR P3, TM3P, TH3P | Pack of 3, Use up to 6 months |
| Pre-filter | Pack of 10, replaced when blocked or dirty | |
| Pre-filter – Anti-odour | Pack of 10, replaced when blocked or odour present | |
| Gas cartridge A1B1E1K1 | Pack of 1, Use up to 6 months | |
| HEPA filter for the Gas cartridge | Pack of 3, Use up to 6 months | |
| Operation Conditions
|
Altitude | Up to 5000m |
| Temperature | – 10°C to 50°C (14°F to 122°F) | |
| Humidity | Up to 95% (non-condensing) | |
| Storage Condition
|
Temperature and Humidity
|
Short period < 1 month -5°C to 45°C 23°F to 113°F), 65±20%RH |
| Within 3 months -5°C to 35°C (23°F to 95°F), 65±20%RH | ||
| Long period > 3 months 0°C to 35°C (32°F to 95°F), 65±20%RH | ||
| Battery Run Time
|
颗粒物 | Minimum 4 hours, up to 16 hours in Eco State, 8 hours in Boost State |
| 气体 | Minimum 4 hours, up to 9 hours | |
| Battery Charging
|
Within the unit with an external charger provided, 0°C to 35°C | 3.5 hours to 95% (fast flashing LED) |
| 4 hours full charge (Constant LED) | ||
| Battery Life | Typical 3 years, replaceable | |
| Peak Flow
|
颗粒物 | Over 220 l/min |
| 气体 | Over 140 l/min | |
| Manufacturer Minimum Flow Condition
|
颗粒物 | 120 l/min |
| 气体 | 95 l/min | |
| Alarms
|
Filter-Blocked Alarm | 2 beeps per second, with flashing Red LED |
| Low Battery Alarm | 3 beeps per second | |
| Flow Capacity Check | Peak flow check | 3 levels |
| Noise Level
|
Leq – high exertion | Up to 71dB |
| Leq – typical | < 65dB | |
| Weight
|
Power Unit – Particulate | 437g |
| Power Unit – Gas | 429g | |
| 使用寿命 | Motor/Blower | 10年 |
| AC Charge Adaptor
|
Input | 100 ~ 240VAC, 47~60 Hz |
| Output | 13.8VDC, 1A | |
| DC Jack plug | 1.1mm pin, 3.0mm barrel |
Aimwell™ AYO™ WX FFM
Aimwell™ AYO™ WX MAIN UNIT
• EN 12941: 2023 TH3
see more: AYO WX Certifications
RELATED PRODUCTS
澳大利亚标准认证
Australian Owned & Operated
Free Shipping within Australia
*for purchases with a minimum order value of $100.