AYO™ WX FFM-LF Loose-Fitting Full-Face Mask
PAPR Systems
Choose your system:
Verify the Mask Size
| FFM-LF (Loose-Fitting) | |
| Mask Size | Recommended Height |
| Medium – Large | 95-140 mm |
AYO™ WX FFM-LF PAPR – a loose-fitting full-face mask PAPR series, comprising 2 models:
- AYO™ WX FFM-LF P-Standard Loose-Fitting Full-Face Mask PAPR System (Discontinued)
- AYO™ WX FFM-LF P-Boost Loose-Fitting Full-Face Mask PAPR System
This series is designed for demanding breathing protection in dusty or toxic industrial settings, such as:
- Formwork.
- Building demolition and restoration.
- Concrete patching.
- Tunnelling.
- Mining.
It is also designed to be compatible with facial hair and to provide eye and face protection.
Different from the AYO™ WX FFM-DS Double-Seal Tight-Fitting PAPR, its full-face mask doesn’t include an inner mask.
Although its protection level is less than that of a well-fitted AYO WX FFM-DS PAPR when breathing hard, it can still provide PAPR P3/TH3 protection for light to moderate exertion.
This state-of-the-art and patented powered full-face mask represents the best PAPR technology in the world. It sets a new standard for loose-fitting full-face powered respirators.
- Key Features
- Key Benefits
- Technical Specifications
- Training Videos
- User Manuals and Quick Guides
- Certifications
- Certified to loose-fitting Standard EN 12941:2023 as TH3, no fit testing is required.
- No hose, no belt, easy to don and doff.
- Up to 220L/Min peak flow (P-Boost).
- Advanced breath-responsive flow control.
- Exceptionally Clear and scratch-resistant lens with a magnificent field of view.
- Face seal Kit add-on: designed for workers with longer beards.
- Shower Kit add-on: for decontamination showers
- Lighter, easier to clean and maintain than traditional PAPRs.
- The loose-fitting respirator systems are specifically designed for workers with facial hair without the need for fit testing but still provide 10 times better protection (TH3) than well-fitted (clean-shaven) P3 non-powered respirators.
- Increasing productivity for work involving high exertion, substantial body movement, and in confined spaces.
- Ensuring protection and WHS compliance economically.
Technical Specifications (Complete AYO WX Series):
| Compliance | Respiratory Protection Standards | AYO WX FFM-LF P-Boost Loose-Fitting Full-Face Mask PAPR System |
EN 12941:2023 TH3P MS AS/NZS 1716:2012 PAPR-P3 |
| AYO WX HFM P-Boost Dual-Fitting Standard Half-Face Mask PAPR System AYO WX HFM-W P-Boost Dual-Fitting Welding |
EN 12941:2023 TH3P MS EN 12942: 2023 TM3P MS (TBA) AS/NZS 1716:2012 PAPR-P3 |
||
| AYO WX FFM-DS P-Boost Double-Seal Full-Face Mask PAPR System AYO WX FFM-DS Gas Double-Seal AYO WX HFM Gas Tight-Fitting Standard AYO WX HFM-W Gas Tight-Fitting Welding |
EN 12942: 2023 TM3P MS (TBA) EN 12942: 2023 TM3A1B1E1K1P MS (TBA) AS/NZS 1716:2012 PAPR-P3 “MS” indicates the product has passed all the mechanical strength tests per EN12941:2023 and EN12942:2023. |
||
| Eye/Face Protection | AYO WX FFM-LF, AYO WX FFM-DS | AS/NZS 1337.1:2010 (Low Impact and flame impingement Protection) |
|
| Respiratory Protection Certification | Australia | CMI ProdCert, Lic: PC10112 | |
| CE Mark | CE 2384 Module B+D | ||
| EMC | CISPR 11: 2017+A1:2020 | ||
| EN IEC 61326-1:2021 | |||
| EN IEC 61326-2-2:2021 | |||
| EN IEC 61000-3-2:2019/A1:2021 | |||
| EN 61000-3-3:2013/A2:2021 | |||
| 47 CFR FCC part 15, Subpart B | |||
| ANSI C63.4:2014 | |||
| Safety | AS/NZS 61558, EN 61558, UL 62368 | ||
| Filter Options | Main Filter – Long Life P3, TM3P | Pack of 3, use up to 6 months |
| Main Filter – P3 Standard | Pack of 3, use up to 3 months | |
| Pre-filter | Pack of 10, replaced when blocked or dirty | |
| Pre-filter – Anti-odour | Pack of 10, replaced when blocked or odour present | |
| Gas cartridge A1B1E1K1 | Pack of 1, use up to 6 months | |
| HEPA filter for the Gas cartridge TM3P | Pack of 3, Use up to 6 months | |
| Operation Conditions | Altitude | Up to 5000m |
| Temperature | – 10°C to 50°C (14°F to 122°F) | |
| Humidity | Up to 95% (non-condensing) | |
| Storage Condition | Temperature and Humidity | Short period < 1 month -5°C to 45°C 23°F to 113°F), 65±20%RH |
| Within 3 months -5°C to 35°C (23°F to 95°F), 65±20%RH | ||
| Long period > 3 months 0°C to 35°C (32°F to 95°F), 65±20%RH | ||
| Battery Run Time | Particulate | Minimum 4 hours, typically 16 hours for Eco State, 8 hours for Boost State |
| Gas | Minimum 4 hours, typically 9 hours | |
| Battery Charging | Within the unit with an external charger provided, 0°C to 35°C | 3.5 hours to 95% (fast flashing LED) |
| 4 hours full charge (Constant LED) | ||
| Battery Life | Typical 3 years, replaceable | |
| Peak Flow | Particulate | Over 220 l/min |
| Gas | Over 140 l/min | |
| Manufacturer Minimum Flow Condition | Particulate | 120 l/min |
| Gas | 95 l/min | |
| Alarms | Filter-Blocked Alarm | 2 beeps per second, flashing Red LED |
| Low Battery Alarm | 3 beeps per second | |
| Flow Capacity Check | Peak flow check | 3 levels |
| Noise Level | Leq – high exertion | Up to 71dB |
| Leq – typical | < 65dB | |
| Weight | Power Unit – Particulate | 437g |
| Power Unit – Gas | 429g | |
| Service life | Motor/Blower | 10 years |
| AC Charge Adaptor | Input | 100 ~ 240VAC, 47~60 Hz |
| Output | 13.8VDC, 1A | |
| DC Jack plug | 1.1mm pin, 3.0mm barrel |
Aimwell™ AYO™ WX FFM
- Full-Face Mask System Donning and Doffing
- Full-Face Mask
- Full-Face Plug Sheath
- FFM Face Seal Kit
Aimwell™ AYO™ WX Main Unit
- Changing Filters
- Main Unit Basic Operation
- Control Panel
- Operation Mode
- Basic Diagnostics
- Battery Charging
- Battery Replacement
- Older version (before 2025)
- New version (after 2025)
- Push-Fit & Twist-Release Connection Cleaning
- Main Unit Dust Sleeve
- Cleaning
Aimwell™ AYO™ TALK-MIC
AYO™ WX User Manuals:
AYO™ WX FFM Quick Guides:
- AS/NZS 1716: 2012 PAPR P3
- EN 12941: 2023 TH3
see more: AYO WX Certifications