AYO™ WX HFM-W Welding Half-Face Mask
PAPR Systems

Configure your system:

Each system of the series includes everything to get started, but to save the trouble of buying new filters soon, we recommend buying together some packs of spare filters according to your normal working conditions and frequency of use.

  Select the Mask Size

MASK SIZES
Small Medium Large
90-105 mm 105-120 mm 120-135 mm

 

Note: If AYO WX mask doesn’t fit the user properly, the protection level could be compromised.

AYO™ WX HFM-W PAPR– a dedicated welding half-face mask PAPR series, comprising 3 models:

  • AYO™ WX HFM-W P-Standard Welding Half-Face Mask PAPR System (Discontinued)
  • AYO™ WX HFM-W P-Boost Welding Half-Face Mask PAPR System
  • AYO™ WX HFM-W Gas Welding Half-Face Mask PAPR System (coming soon!)

This series has the same Main Unit as the WX HFM system, except its masks are optimised for welding fume protection.

  • More streamlined mask, designed to be compatible with most common welding helmets.
  • Highest multiple protection classes P3/TM3/TH3.
  • No hose, no belt, easy to don and doff.
  • Up to 220L/Min peak flow (P-Boost).
  • Advanced breath-responsive flow control.
  • Face seal add-on: designed for workers with longer beards.
  • Easier to clean and maintain than traditional PAPRs.
  • A low-cost and low-profile alternative to traditional integrated welding helmet + PAPR systems.
  • Beard compatible.
  • Allows you to use your existing welding helmet.
  • An ideal upgrade from non-powered half-face respirators or P3 dust masks for welding fume protection.

Technical Specifications (Complete AYO WX Series):

Compliance Respiratory Protection Standards AYO WX FFM-LF P-Boost Loose-Fitting
Full-Face Mask PAPR System
EN 12941:2023 TH3P MS
AS/NZS 1716:2012 PAPR-P3
AYO WX HFM P-Boost Dual-Fitting Standard
Half-Face Mask PAPR System

AYO WX HFM-W P-Boost Dual-Fitting Welding
Half-Face Mask PAPR System

EN 12941:2023 TH3P MS
EN 12942: 2023 TM3P MS (TBA)
AS/NZS 1716:2012 PAPR-P3
AYO WX FFM-DS P-Boost Double-Seal
Full-Face Mask PAPR System

AYO WX FFM-DS Gas Double-Seal
Full-Face Mask PAPR System

AYO WX HFM Gas Tight-Fitting Standard
Half-Face Mask PAPR System

AYO WX HFM-W Gas Tight-Fitting Welding
Half-Face Mask PAPR System

EN 12942: 2023 TM3P MS (TBA)
EN 12942: 2023 TM3A1B1E1K1P MS (TBA)
AS/NZS 1716:2012 PAPR-P3

“MS” indicates the product has passed all the mechanical strength tests per EN12941:2023 and EN12942:2023.

Eye/Face Protection AYO WX FFM-LF, AYO WX FFM-DS AS/NZS 1337.1:2010
(Low Impact and flame impingement Protection)
Respiratory Protection Certification Australia CMI ProdCert, Lic: PC10112
CE Mark CE 2384 Module B+D
EMC CISPR 11: 2017+A1:2020
EN IEC 61326-1:2021
EN IEC 61326-2-2:2021
EN IEC 61000-3-2:2019/A1:2021
EN 61000-3-3:2013/A2:2021
47 CFR FCC part 15, Subpart B
ANSI C63.4:2014
Safety AS/NZS 61558, EN 61558, UL 62368
Filter Options Main Filter – Long Life P3, TM3P Pack of 3, use up to 6 months
Main Filter – P3 Standard Pack of 3, use up to 3 months
Pre-filter Pack of 10, replaced when blocked or dirty
Pre-filter – Anti-odour Pack of 10, replaced when blocked or odour present
Gas cartridge A1B1E1K1 Pack of 1, use up to 6 months
HEPA filter for the Gas cartridge TM3P Pack of 3, Use up to 6 months
Operation Conditions Altitude Up to 5000m
Temperature – 10°C to 50°C (14°F to 122°F)
Humidity Up to 95% (non-condensing)
Storage Condition Temperature and Humidity Short period < 1 month -5°C to 45°C 23°F to 113°F), 65±20%RH
Within 3 months -5°C to 35°C (23°F to 95°F), 65±20%RH
Long period > 3 months 0°C to 35°C (32°F to 95°F), 65±20%RH
Battery Run Time Particulate Minimum 4 hours,
typically 16 hours for Eco State, 8 hours for Boost State
Gas Minimum 4 hours, typically 9 hours
Battery Charging Within the unit with an external charger provided, 0°C to 35°C 3.5 hours to 95% (fast flashing LED)
4 hours full charge (Constant LED)
Battery Life Typical 3 years, replaceable
Peak Flow Particulate Over 220 l/min
Gas Over 140 l/min
Manufacturer Minimum Flow Condition Particulate 120 l/min
Gas 95 l/min
Alarms Filter-Blocked Alarm 2 beeps per second, flashing Red LED
Low Battery Alarm 3 beeps per second
Flow Capacity Check Peak flow check 3 levels
Noise Level Leq – high exertion Up to 71dB
Leq – typical < 65dB
Weight Power Unit – Particulate 437g
Power Unit – Gas 429g
Service life Motor/Blower 10 years
AC Charge Adaptor Input 100 ~ 240VAC, 47~60 Hz
Output 13.8VDC, 1A
DC Jack plug 1.1mm pin, 3.0mm barrel

Aimwell™ AYO™ WX HFM

  1. Donning and Doffing
  2. Face Seal Kit
  3. Cleaning

Aimwell™ AYO™ WX Main Unit

  1. Changing Filters
  2. Main Unit Basic Operation
  3. Push-Fit & Twist-Release Connection Cleaning
  4. Main Unit Dust Sleeve
  5. Cleaning

Aimwell™ AYO™ TALK-MIC

  • AS/NZS 1716: 2012 PAPR P3
  • EN 12941: 2023 TH3
  • EN 12942: 2023 TM3, TM3A1B1E1K1 (Coming soon)

see more: AYO WX Certifications

RELATED PRODUCTS

AYO WX HFM Standalone Face Seal (Pack of 3)

$65.50

AYO WX PAPR P3 Main Filter – Long Life (Pack of 3)

$79.30

AYO WX Pleated Pre-Filter (Pack of 10)

$31.20

AYO WX Anti-odour Pre-Filter (Pack of 10)

$52.00

Certified with Australian Standard

Australian Owned & Operated

Free Shipping within Australia

*for purchases with a minimum order value of $100.

30 Day Product Return

*terms and conditions apply.
0
    0
    Your Cart
    Your cart is emptyReturn to Shop